Emergency Opener
Material:
Base part: Nylon PA, glass fibre reinforced
Push button: Nylon PA, glass fibre reinforced
Unlocking plate: Steel
Surface: Unlocking plate: Zinc plated
Color:
Base part: Black
Push button: Red
Fastening: From the front, using two socket head screws DIN 912 M6 x 20
Pack Quantity: 1 piece
Part # 0957409
Slam Latch PROe
Description:
For an easy and secure latching and locking of doors and flaps, no mechanical preparation needed for the assembly; safe against disassembling in the locked position;
plug M12, 8-pin, for left or right-hand door, connector position at the bottom or at the top;
system voltage 24 V;
UL-certified, tested according to B6;
safety class category 4, PLe
Part # 095740107xxARA-A4SR
Slam Latch PRO
Description:
For an easy and secure latching and locking of doors and flaps, no mechanical preparation needed for the assembly; safe against disassembling in the locked position
Part # 0957404
Slam Latch Compact
Description:
For an easy and secure latching and locking of doors and flaps, no mechanical preparation needed for the assembly; safe against disassembling in the locked position
Part # 0957408
Mounting and Installation
Technical Data
min. Value | typ. Value | max. Value | Unit | |
Housing material | Die-cast aluminum | |||
Dimensions | See dimensioned drawing | mm | ||
Weight | 380.0 | g | ||
Ambient temperature at UB = Dc 24 V | – 20 | – | + 55 | °C |
Safety class | III | |||
Degree of contamination | 3 | |||
Installation position | any | |||
Connection | plug M12, 8-pin | |||
Operating voltage UB | 24 ±15 % | V DC | ||
for the approvel according to UL the following applies | Operation only with UL class 2 power supply or equivalent measures | |||
Current consumption | – | – | 40 | mA |
Switching load according to UL | class 2 | |||
External fuse (operating voltage) | 0.25 | – | 3 | A |
Safety outputs | Semicunductor outputs, p-switching, short-circuit-proof | |||
Output voltage HIGH U | UB -1.5 | – | UB | V DC |
Output voltage LOW U | – | 1 | V DC | |
Switching current per safety output | 1 | – | 100 | mA |
Utilization category according to EN IEC 60947-5-2* | DC-13 24V 100 mA | Caution: outputs must be protected with a free-wheeling diode in case of inductive loads | ||
Category | Category 4 | |||
Performance Level | PL e |
Connection Material
Pin | Function | Pin | Function |
---|---|---|---|
1 | UB | 1 | UB |
2 | OA (FO1A) | 2 | IA (FI1A) |
3 | 0 V | 3 | 0 V |
4 | OB (FO1B) | 4 | IB (FI1B) |
5 | RST | 5 | RST |
Description | Version | Part # |
---|---|---|
Short-circuit plug | M12, 4-pole, Pin | 0957WS |
Y-distributor M12 with connection cable | M12, 1×8-pole, 2×5-pole | 0957WY02 |
Y-distributor | M12, 1×8-pole, 2×5-pole | 0957WY |
Connection cable PVC, 8-pin, open cable end | M12,8-pole,5m M12,8-pole,10m M12,8-pole,20m | 0957WL5 0957WL10 0957WL20 |